Pollution Control Products DC-2A Oven
DC-2A Oven
Stock #744New Machine; $23,500
New Pollution Controll Products Model DC-2A Furnace
Furnace Includes:
Four 3 foot sections of insulated stainless steel chimney, adjustable roof flashing, storm collar with weatherproof sealant tape, rain cap, instruction manual, cart, and exterior cart tracks.
Dimensions |
Width |
Depth |
Height |
Inside |
36” |
21” |
33” |
Footprint |
62” |
46” |
46” |
Cart Inside |
32” |
21” |
12” |
Electrical |
115V / 60 Hz / 7 AMP / 1 PH |
Natural Gas |
300,000 BTU/Hr. Pressure 7" WC Min. and 15” WC Max. |
Water |
40/100 (Low/High) PSI |
Features of the DC-Dry CleanerTM Furnace
Back-up Water Spray System:
- Used to extinguish any fire that might develop in the furnace to prevent damage to the parts being cleaned.
5-Layer Wall Protection:
- Corrosion-resistant barrier 1/8” thick is applied to furnace wall prior to installing insulation. Adds years to the useful life of the furnace. Insulation is protected by perforated metal.
Diagnostic Panel:
- Performs an operational checklist of the furnace components during start-up and advises the operator of any abnormalities
Commercial Gas Burners:
- Furnace is equipped with Pollution Control SK-225 Industrial Gas Burners designed specifically for incinerator and other similar applications. Features include quiet motor-driven high-output blower, superior no-clog nozzle design, easy maintenance, and rugged heavy-duty construction. All flame-safeguard components and associated wiring are located outside the blast tube and blower housing, away from destructive heat. The blast tube contains only electrodes that provide ignition and flame detection. There is nothing to clog and no wires to burn.
EPA Permitting Assistance:
- At customer’s request, we will fill out all permits required and supply all necessary stack test data and supporting documentation.
Floor:
- Floor insulated with castable refractory insulation.
Door:
- Door open 95º or more.
Part Temperature Monitoring System:
- Thermal-couple wire can be attached to part to indicate part temperature during cleaning cycle.